MB A6K4 is a high capacity mixed bed ion exchange resin consisting of a mixture of strongly basic anion resin and a strongly acidic cation resin for direct water purification.The conductivity is about 0.06 µm/cm.Suitable for use in non-regenerable cartridges, high efficiency deionisation for silica removal and ultra pure water applications.Packed in 25 litre bagsPolymer matrix: gel polystyrene cross-linked with DVB.Ionic form, as supplied: H+ / OH-Physical shape and appearance: Spherical beadsSphericity: Min. 95%Particle size range (US Standard Screen): 1.25 - 0.315mm, wet.Particle size: +1.2mm < 5% ; -0.3mm < 1%Water retention H+: 45 - 50%Water retention OH-: 53 - 60%Shipping weight (approx.): 700-740 g/lMax. Temp. non-regenerative: 100°CMax. Temp. regenerative: 60°CpH-value range: 0-14Recommended operating conditions:Minimum bed depth should be 0.6m (24")Service flow rate should be 20-60 BV/hourProlonged exposure to strong oxidising agents such as chlorine, hydrogen peroxide and concentrated nitric acid will deteriorate the structural backbone of the resin and should be avoided.Mixture Resin:Anions: 60%Cations: 40%Purchase options:Single purchase - 25 ltr. (item no. 896495)1/2 pallet - 500 ltr. (Art.-No. 896496)1 pallet - 1050 ltr. (art.-no. 896497)
Proposed use: for the regeneration of water softeners
Composition: evaporated salt (min. 99.9% NaCl)
Dimensions / weight of tablet: ø25mm / 14g
Moisture content: < 0.08
Filling weight: 10kg per sack
Type of packaging: PE film
Storage description: store dry and well closed
Certifications: ISO 9001, ISO 14001 and IFS
Standard: The product complies with the following standards.
EN 973:2009
Products for the treatment of water intended for human consumption - Sodium chloride for regenerating ion exchange resins -Type A
EN 16401:2013
Products for the treatment of swimming pool water - Sodium chloride for use in electrochemical chlorine production plants - Type A
EN 14805:2022
Products for the treatment of water intended for human consumption - Sodium chloride for on-site electrochemical production of chlorine by membrane-free processes - Type 1
EN 16370:2022
Products for the treatment of water intended for human consumption - Sodium chloride for the on-site electrochemical production of chlorine by means of membrane cells - Quality 2
Purchase options:
Single purchase: 1x 10kg sack (Art.-No. 896467)
Pallet purchase: 100x 10kg sacks (Art.-No. 896498)
Proposed use: for the regeneration of water softeners
Composition: evaporated salt (min. 99.9% NaCl)
Dimensions / weight of tablet: ø25mm / 14g
Moisture content: < 0.08
Filling weight: 25kg per sack
Type of packaging: PE film
Storage description: store dry and well closed
Certifications: ISO 9001, ISO 14001 and IFS
Standard: The product complies with the following standards...
EN 973:2009
Products for the treatment of water intended for human consumption - Sodium chloride for regenerating ion exchange resins -Type A
EN 16401:2013
Products for the treatment of swimming pool water - Sodium chloride for use in electrochemical chlorine production plants - Type A
EN 14805:2022
Products for the treatment of water intended for human consumption - Sodium chloride for on-site electrochemical production of chlorine by membrane-free processes - Type 1
EN 16370:2022
Products for the treatment of water intended for human consumption - Sodium chloride for the on-site electrochemical production of chlorine by means of membrane cells - Quality 2
Purchase options:
Single purchase: 1x 25kg sack (Art.-No. 896468)
Pallet purchase: 40x 25kg sacks - 1000 kg (Art.-No. 896500)
Maximum capacity at 300 µS input water:
900 liters (6 ltr. MB resin filling)
Plastic cartridges variantsDK-VE 6 - demineralisation cartridge with hole in the head (capacity max. 900 litres at 300µS)DK-VE 10 - demineralisation cartridge with hole in the head (capacity max. 1,500 litres at 300µS)DK-VE 15 - demineralisation cartridge with hole in the head (capacity max. 2,250 litres at 300µS)DK-VE 20 - demineralisation cartridge with hole in the head (capacity max. 3,000 litres at 300µS)DK-VE 25 - demineralisation cartridge with hole in the head (capacity max. 3,750 litres at 300µS)DK-VE 30 - demineralisation cartridge with hole in the head (capacity max. 4,500 litres at 300µS)DK-VE 50 - demineralisation cartridge with hole in the head (capacity max. 7,500 ltr. at 300µS)
Water sterilisation by UV irradiation
The development of water sterilisation using UV radiation has made considerable progress in recent years due to its simplicity and efficiency. The UV-C rays generated, which are significantly more intense than sunlight, are therefore used to disinfect water in order to counteract water contamination. They make it possible to remove legionella, microbes, bacteria, viruses and protozoa while respecting the environment. The irradiation process is therefore an ideal solution for killing microorganisms in water and helps to make it drinkable from a bacteriological point of view. However, it is important to note that water is only considered drinking water once the chemical parameters have been checked and deemed satisfactory.
Applications - Origin of the water
Rainwater: UV treatment extends the range of applications and offers increased safety during use
Well water: Avoidance of possible contamination by pathogens
Tap water: UV treatment extends the area of application and increases safety.
Spring water, surface water: Guarantees constant water quality that is flawless from a bacteriological point of view.
Storage water in containers (caravan, boat...): Use of stored water for sanitary purposes.
Areas of application
General nutrition, bath and shower
Cooking
Large-volume refrigerators
Cold water fountains
Aquarium
Cleaning food
Advantages
Quick and easy installation
Completely physical sterilisation through UV radiation
Natural water treatment without additives and without the risk of chemical overdose
No unpleasant taste or odour
Effective methods for combating microorganisms that cause disease in humans
No toxic by-products
Low maintenance
Water sterilisation by UV irradiation
The development of water sterilisation using UV radiation has made considerable progress in recent years due to its simplicity and efficiency. The UV-C rays generated, which are significantly more intense than sunlight, are therefore used to disinfect water in order to counteract water contamination. They make it possible to remove legionella, microbes, bacteria, viruses and protozoa while respecting the environment. The irradiation process is therefore an ideal solution for killing microorganisms in water and helps to make it drinkable from a bacteriological point of view. However, it is important to note that water is only considered drinking water once the chemical parameters have been checked and deemed satisfactory.
Applications - Origin of the water
Rainwater: UV treatment extends the range of applications and offers increased safety during use
Well water: Avoidance of possible contamination by pathogens
Tap water: UV treatment extends the area of application and increases safety.
Spring water, surface water: Guarantees constant water quality that is flawless from a bacteriological point of view.
Storage water in containers (caravan, boat...): Use of stored water for sanitary purposes.
Areas of application
General nutrition, bath and shower
Cooking
Large-volume refrigerators
Cold water fountains
Aquarium
Cleaning food
Advantages
Quick and easy installation
Completely physical sterilisation through UV radiation
Natural water treatment without additives and without the risk of chemical overdose
No unpleasant taste or odour
Effective methods for combating microorganisms that cause disease in humans
No toxic by-products
Low maintenance
Water sterilisation by UV irradiation
The development of water sterilisation using UV radiation has made considerable progress in recent years due to its simplicity and efficiency. The UV-C rays generated, which are significantly more intense than sunlight, are therefore used to disinfect water in order to counteract water contamination. They make it possible to remove legionella, microbes, bacteria, viruses and protozoa while respecting the environment. The irradiation process is therefore an ideal solution for killing microorganisms in water and helps to make it drinkable from a bacteriological point of view. However, it is important to note that water is only considered drinking water once the chemical parameters have been checked and deemed satisfactory.
Applications - Origin of the water
Rainwater: UV treatment extends the range of applications and offers increased safety during use
Well water: Avoidance of possible contamination by pathogens
Tap water: UV treatment extends the area of application and increases safety.
Spring water, surface water: Guarantees constant water quality that is flawless from a bacteriological point of view.
Storage water in containers (caravan, boat...): Use of stored water for sanitary purposes.
Areas of application
General nutrition, bath and shower
Cooking
Large-volume refrigerators
Cold water fountains
Aquarium
Cleaning food
Advantages
Quick and easy installation
Completely physical sterilisation through UV radiation
Natural water treatment without additives and without the risk of chemical overdose
No unpleasant taste or odour
Effective methods for combating microorganisms that cause disease in humans
No toxic by-products
Low maintenance
Product description: UV lamp 25W / 40W for Cintropur UV2100 / UV4100 flow-through fitting.
The 25W / 40W UV lamp is an essential accessory for the Cintorpur UV2100 / UV4100 flow-through fitting, ensuring maximum efficiency and safety when disinfecting water. With its powerful 25 / 40 watt output, this lamp ensures reliable and thorough disinfection of the water.
Outstanding features:
Annual replacement required: To ensure constant and effective disinfection of the water, it is mandatory to replace the UV lamp once a year. This ensures that the lamp always provides optimum performance and ensures reliable disinfection.
Continuous operation around the clock: The UV lamp is designed to operate 24 hours a day, 7 days a week. This continuous use enables constant sterilisation of the water, which is particularly important in environments with high hygiene requirements, such as companies, clinics or farms.
Protection from moisture and fingerprints: To ensure the longevity and efficiency of the lamp, it is essential to protect it from moisture and fingerprints. This can be achieved by proper installation in the UV2100 / UV4100 flow-through fitting as well as regular cleaning and maintenance.
Effective disinfection through UV technology: UV light is known for its effectiveness in killing bacteria, viruses and other micro-organisms in water. The UV lamp utilises this technology to ensure thorough, reliable disinfection of the water and provide os with a safe water supply.
UV lamp 25W: Insert for UV2100 and TRIO UV 25W
UV lamp 40W: Insert for UV4100, DUO-UV and TRIO-UV 40W
Product description: UV lamp 25W / 40W for Cintropur UV2100 / UV4100 flow-through fitting.
The 25W / 40W UV lamp is an essential accessory for the Cintorpur UV2100 / UV4100 flow-through fitting, ensuring maximum efficiency and safety when disinfecting water. With its powerful 25 / 40 watt output, this lamp ensures reliable and thorough disinfection of the water.
Outstanding features:
Annual replacement required: To ensure constant and effective disinfection of the water, it is mandatory to replace the UV lamp once a year. This ensures that the lamp always provides optimum performance and ensures reliable disinfection.
Continuous operation around the clock: The UV lamp is designed to operate 24 hours a day, 7 days a week. This continuous use enables constant sterilisation of the water, which is particularly important in environments with high hygiene requirements, such as companies, clinics or farms.
Protection from moisture and fingerprints: To ensure the longevity and efficiency of the lamp, it is essential to protect it from moisture and fingerprints. This can be achieved by proper installation in the UV2100 / UV4100 flow-through fitting as well as regular cleaning and maintenance.
Effective disinfection through UV technology: UV light is known for its effectiveness in killing bacteria, viruses and other micro-organisms in water. The UV lamp utilises this technology to ensure thorough, reliable disinfection of the water and provide os with a safe water supply.
UV lamp 25W: Insert for UV2100 and TRIO UV 25W
UV lamp 40W: Insert for UV4100, DUO-UV and TRIO-UV 40W
Water sterilisation by UV irradiation
The development of water sterilisation using UV radiation has made considerable progress in recent years due to its simplicity and efficiency. The UV-C rays generated, which are significantly more intense than sunlight, are therefore used to disinfect water in order to counteract water contamination. They make it possible to remove legionella, microbes, bacteria, viruses and protozoa while respecting the environment. The irradiation process is therefore an ideal solution for killing microorganisms in water and helps to make it drinkable from a bacteriological point of view. However, it is important to note that water is only considered drinking water once the chemical parameters have been checked and deemed satisfactory.
Applications - Origin of the water
Rainwater: UV treatment extends the range of applications and offers increased safety during use
Well water: Avoidance of possible contamination by pathogens
Tap water: UV treatment extends the area of application and increases safety.
Spring water, surface water: Guarantees constant water quality that is flawless from a bacteriological point of view.
Storage water in containers (caravan, boat...): Use of stored water for sanitary purposes.
Areas of application
General nutrition, bath and shower
Cooking
Large-volume refrigerators
Cold water fountains
Aquarium
Cleaning food
Advantages
Quick and easy installation
Completely physical sterilisation through UV radiation
Natural water treatment without additives and without the risk of chemical overdose
No unpleasant taste or odour
Effective methods for combating microorganisms that cause disease in humans
No toxic by-products
Low maintenance
Water sterilisation by UV irradiation
The development of water sterilisation using UV radiation has made considerable progress in recent years due to its simplicity and efficiency. The UV-C rays generated, which are significantly more intense than sunlight, are therefore used to disinfect water in order to counteract water contamination. They make it possible to remove legionella, microbes, bacteria, viruses and protozoa while respecting the environment. The irradiation process is therefore an ideal solution for killing microorganisms in water and helps to make it drinkable from a bacteriological point of view. However, it is important to note that water is only considered drinking water once the chemical parameters have been checked and deemed satisfactory.
Applications - Origin of the water
Rainwater: UV treatment extends the range of applications and offers increased safety during use
Well water: Avoidance of possible contamination by pathogens
Tap water: UV treatment extends the area of application and increases safety.
Spring water, surface water: Guarantees constant water quality that is flawless from a bacteriological point of view.
Storage water in containers (caravan, boat...): Use of stored water for sanitary purposes.
Areas of application
General nutrition, bath and shower
Cooking
Large-volume refrigerators
Cold water fountains
Aquarium
Cleaning food
Advantages
Quick and easy installation
Completely physical sterilisation through UV radiation
Natural water treatment without additives and without the risk of chemical overdose
No unpleasant taste or odour
Effective methods for combating microorganisms that cause disease in humans
No toxic by-products
Low maintenance
High-quality conductivity meter for conductivity monitoring
Our innovative conductivity meter has been specially developed for monitoring conductivity in ultrapure water (demineralised water) and has a 4-20 mA signal output that enables easy integration into higher-level control systems.The measurements are temperature-compensated, which ensures greater accuracy. With a measuring range of 0 to 2 µS/cm, our device is particularly suitable for monitoring low conductivities, such as those typically found in mixed-bed ion exchanger cartridges. The limit value is displayed by means of 2 LEDs (green/red) on the top of the device. An acrylic glass cover ensures that the current status is immediately visible.
The device has a ¾ screw thread, which can be customised for easy and safe installation. There is also the option of customisation in terms of the LEDs, including the measuring range and a private label.
Our high-quality conductivity meter offers a reliable solution for conductivity monitoring in medical areas to fulfil the guidelines and recommendations of the DGSV.
Our measuring device is also particularly suitable for mixed bed cartridge monitoring in the clinical environment.
Standard LED configuration (1 green LED, 1 red LED):
<0.5 µS/cm = green
>0.5 µS/cm to <1.0 µS/cm = green/red flashing
>1 µS/cm = red
measuring range:
0-5 μS/cm
|
potential-free relay contact:
with
Conductivity meter for conductivity monitoring
Our innovative conductivity meter was developed specifically for monitoring the conductivity of aqueous solutions. With a measuring range of 0 to 5 µS/cm, our device is particularly suitable for monitoring low conductivities, which are typically used in the following processes:
Mixed bed cartridges
demineralisation
Reverse osmosis (2-stage)
EDI (electrode ionisation)
The limit values are indicated by means of digital displays with 2 preset limit values and 2 LEDs (green/red) for visualisation.
The device has a screw-in thread of ¾", which can be customised for easy and safe installation. There is also the option of customised versions with regard to the measuring range and a private label.
Added value
Operation at 9 V DC via supplied plug-in power supply unit
1 potential-free relay with switchable mode of operation of relay control
Limit value display optically by means of LEDs
Our 4- or 8- channel system allows the processing of up to four or eight measurement signals. For this purpose, 4-20 mA/ RS232 as well as Modbus RTU are available as signal inputs. Based on the received data a visualization as well as a trend display takes place. Through modular addition of optional modules (slaves) the realization of popular control concepts is possible.Advantages:Simple operation
Integration of the Testomat® device world
Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® housingModular function range expandable by NeoTec slave modules (measure, control, control)Available as installation variant or structure variant
Contents:
NeoTecMaster® 5 inch - 4 channel systemNeoTec Slave 4-20mA module (inputs: 8x 20mA)NeoTecMaster® IP66 housing for 5" display, light grey with front foilUSB stick for NeoTecMaster® 8GInstallation of NeoTecMaster® in housing incl. parameterisation and cabling of the NeoTecMaster®Universal power supply 24V/6A DC (100-240V AC) (144 Watt)
Pyrogen filterA pyrogen filter is a special type of filter used in water treatment to remove pyrogens from the water. Pyrogens are substances that can cause an immunological reaction in the body, in particular an increase in body temperature. As a rule, these are endotoxins that are released by bacteria such as Escherichia coli (E. coli). The pyrogen filter consists of a filter element that has a very fine pore size, typically in the range of 0.1 to 0.2 micrometres. This allows the filter to effectively retain particles and microorganisms, including pyrogenic bacteria that may be present in the water. In the modular water treatment system, the pyrogen filter is used after other pre-treatment stages such as filtration and disinfection. After the water has been cleaned of particles and microorganisms, it is passed through the pyrogen filter to remove any pyrogens. Pyrogen filters are particularly important in industries where the absence of pyrogens in the water is crucial, for example in the ambulatory care sector to ensure the optimum quality of instruments for operations. Overall, pyrogen filters play an important role in water treatment to ensure the quality and purity of water and minimise potential exposure to pyrogenic substances.
Language in the display:
German
|
Performance/execution:
230 V/50-60 HZ
The process photometer Testomat 2000® automatically determines water hardness, carbonate hardness, the p-value or the minus m-value via titration. It is ideal for monitoring the water quality of water treatment, water blending and drinking-water plants. Monitoring and quality control of softening plants with and without blending (Testomat 2000® reagent TH 2005–2250)Monitoring and quality control of decarbonisation plants (Testomat 2000® reagent TC 2050–2100) Measuring acidic values in decarbonisation and desalination plants (Testomat 2000® reagent TM 2005) Monitoring of steam boilers (Testomat 2000® reagent TP 2100).Performance profile:
Menu-driven operation and programming via plain text display
Determinal measuring ranges of residual hardness, total hardness, carbonate hardness, minus m value, p value by indicator selectionSelection of hardness units in ° dH, ° f, ppm CaCO3 or mmol / l
High-precision titration using a piston dosing pump
Analysis initiation:
- Automatic interval operation (Interval pause adjustable from 0–99 min)
- External control
- Dynamic (fatigue-dependent interval operation)
- Quantity dependent via contact water meter
Two independent limits with hysteresis (1, 2 oder 3 bad analyzes) and adjustable switching functionsMonitoring of two measuring points (Switching by external solenoid valves)Internal error documentation
Programmable service address
Indicator quantities: 100 and 500 ml bottles
Programmable maintenance interval for maintenance request
The Testomat® 808 is a compact analyzer for the online measurement of water hardness according to the principle of " limit value monitoring by color change ". The Testomat® style="letter-spacing: 0px;"> 808 is a combination of the latest technologies based upon decades of international Testomat® experience.Applications of continuous residual hardness monitoring are for example:
Reverse osmosis plants
Boiler feed water supply
Soft water for commercial puposes
Pure water systems
Performance profile:Limit value indication (not exceeded or exceeded: green / red LED)
Modern indicator pump system
Automatic measuring process with low water consumption
Direct error and indicator quantity indication
Internal and external flushing of the measuring chamber by manual control
Control of an external rinsing valve
Three potential-free relays for:
External rinsing valve control
Limit value evaluation
External control and / or alarm processing
Safety check for 72 hours operation without supervision
Indicator quantities: 100 and 500 ml bottles
4 - 20 mA interface for defined status and error messages
RS 232 interface for firmware updates
The Testomat® 808 SIO02 is a device that was developed for measuring and monitoring deionised water (fully demineralised water) in medical facilities.
The central importance of silicate monitoring
Silicate measurement using the Testomat® 808 SIO02 is an essential aspect of compliance with a defined limit value. Precise silicate monitoring is particularly important in process water treatment in hospitals in order to prevent deposits on devices and medical devices (MD) and to ensure the effectiveness of the water treatment systems. You can choose between 10 limit values in the range from 0.3 to 1.2 ppm. By regularly monitoring the silicate content and compliance with the limit values, potential problems can be identified at an early stage and suitable measures can be taken to optimise water treatment.
The Testomat® 808 is a compact analyser for online measurement of water hardness according to the principle of "limit value monitoring with colour change" in the measuring range 0.02 - 5 ° dH (0.4 - 89 ppm). Applications of the continuous residual hardness monitoring are e.g.: Reverse osmosis systems, boiler feed water supply Soft water for commercial purposes, ultrapure water systems.
In view of the fact that the Testomat® 808 is suitable for use in multi-parameter systems due to its 4-20mA signal output, we hereby offer you the Testomat® 808 in conjunction with the NeoTecMaster® Multicontroller, which was specially developed by our company, as a package solution at a preferential price.
The 4-channel NeoTecMaster® Multicontroller included in this package enables the processing of up to four measurement signals. Via the 4-20mA NeoTec slave input module connected to the NeoTecMaster®, the data is transmitted to the NeoTecMaster® and used to display the measured value, the trend and the status messages on the 5-inch screen. In addition, the NeoTecMaster® has an RS232 interface as well as a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments).
The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required. This allows the future realisation of further control concepts in a flexible way.
Two modules which fundamentally extend the range of functions and are already included in the scope of delivery are our NeoTec slave relay module and the 4x 4-20mA input module. This allows you to add potential-free relay contacts to the overall system and to integrate and visualise further system technology such as sensors via the 4x 4-20mA input module. You can freely assign the relay contacts to the incoming measurement signals and thus, for example, implement simple limit value-related control concepts as well as output measurement value-related messages.
Further advantages of the NeoTecMaster:
Simple operation Integration of the Testomat® device world, here in connection with the Testomat® 808
Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® enclosure
Modular range of functions can be extended by NeoTec slave and signal converter modules (measurement, control, regulation)
Available as built-in or surface-mounted variant
Structured continuous data recording on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format
In addition, there are the proven functionalities of the Testomat® 808:
Indication of limit value undershoot or overshoot: green / red LED
Modern indicator pump system
Automatic measuring sequence with low water consumption
Direct error and indicator quantity display
Internal and external flushing of the measuring chamber by manual control
Control of an external flush valve
Three potential-free relays for: External flush valve control Limit value evaluation External control and / or alarm processing
Safety check for 72-hour operation without supervision
Indicator quantities: 100 and 500 ml bottles
4 - 20 mA interface for defined status and error messages
RS 232 interface for firmware updates
General information
Water connection and operating pressure: Depending on unit version: 0.3 - 1 bar / 0.3 x 105 to 4 x 105 Pa 1 - 4 bar / 1 x 105 to 4 x 105 Pa (from 4 to 8 bar, a pressure reducer must be used (special accessory))
Water inlet: opaque hose with 6 mm outer diameter/4 mm inner diameter
Water outlet: hose with 6 mm outer diameter/4 mm inner diameter
Water temperature: 10 to 40 °C
From 4 bar, a separately available pressure reducer must be used. Please use only the indicators approved for Testomat® 808!
Optional accessories:
NeoTecMaster unit hood
The Testomat® ECO / EVO automatically determines the water hardness by means of titration. The device is suitable for controlling the water quality of water treatment plants, drinking water systems, industrial boilers and for monitoring process water. Approved for boiler houses | component identification no.: TÜV. WÜH. 21-025 | VdTÜV bulletin water monitoring device 100 and UL-TÜV certified (only version with wide-range power supply unit).The Testomat® style="letter-spacing: 0px;"> EVO TH convinces with new functionalities:Optical water detection when filling the measuring chamber
BOB operation (operation without constant supervision)Import and export of settings (basic programming) with selectable file nameLogging of measurement data and messages / alarms using an integrated SD or optional SDHC card (2GByte)
Firmware update via SD card
LCD graphic display
Multilingual menu with easy switching (internal programming is retained)
Integrated self-test with continuous monitoring
External clear / acknowledge input
Free programmable password
Automatic bleeding of the indicator line
Doors can be changed individually
Range monitoring (fall below limit value1 / exceed limit value 2)
Permitted number of lack of water, freely programmable (for systems with temporarily low water pressure)[#mspacer#]Performance profile:High-precision titration using a piston dosing pump
Analogue output 0/4 - 20 mA
Serial RS232 interface for transfer of measurement data and messages/alarmsProgrammable hardness unit in ° dH, ° f, ppm CaCO3, mmol / l
2 independent limits with adjustable switching functions as well as switching option in accordance with an adjustable number of negativeanalyzes
Analysis initiation:
automatic interval operation (0-99 minutes)
depending on quantity via contact water meter
Indicator quantities: 100 und 500 ml bottles
The Testomat® EVO TH is supplied without a power switch. This is done to comply with the DIN EN 61010-1 safety standard for measuring, control and laboratory equipment. Of course, an external mains switch will be made available to you as a customer for purchase. You can order this from us as a disconnector under article no. 850925, "external cam switch with protection class IP65".
The Testomat® LAB TH and Testomat® LAB TH-R (Remote)determine the water hardness (residual total hardness) fully automatically by titration. The instrument is suitable for controlling the water quality of water treatment plants, drinking water plants, industrial boilers and for monitoring process water.Please note that Testomat® LAB - TH
and Testomat® LAB TH-R was developed for use in multi-parameter systems or for connection to a higher-level control system.
In addition to the 4-20 mA output for transmitting the measured values, this series has an RS232 interface for transmitting the measured values and error & status messages. Furthermore, all data are continuously recorded on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format structured and can be used at any time for detailed observations.The Testomat® LAB TH and TH-R convinces with new functionalities:
Execution of parameterization by SD card or the "Service Monitor" software via mini-USB (on the device side) to USB 2.0 (for example PC/notebook)Multilingual menu navigation software in German, English, French, Dutch, PortugueseFirmware update via SD card
compact design
optimized water detection based on an optical measuring method
Integrated self-test with continuous monitoring
Automatic venting of the indicator line [#mspacer#]Additional functions of the TH-R version:Parameterisation and readout of the unit parameters
via the RS232 interfaceTried and tested performance profile:
High-precision titration using a piston dosing pump
Reliable and low-maintenance operation
Minimal indicator and water consumption
Analog output 4 - 20 mA for transmission of measured values
Programmable hardness unit in °dH, °f, ppm CaCO3, mmol/l
Common alarm output
Indicator quantities: 500 ml bottles
Analysis triggering:
Automatic interval operation (interval pause adjustable from 0-255 minutes)
External analysis input (start/stop)
Hand launchOptional accessories:
OLED display
Protecting cover to increase the IP protection class