Neomeris PPM150 Portable Photometer with USB interface
The PPM 150 multiparameter handheld photometer for the determination of chemical water constituents is equipped with 9 LEDs in the wavelength range from 380 to 810 nm. The device has the following performance profile:
Flexible for many reagents from different manufacturers
Software for documentation and for creating calibration curves
Internal method memory for a maximum of 150 calibration curves
Storage of up to 1,000 data records in the internal data memory; each data record is documented: Date, time, wavelength, reagent used, measurement result, measurement number
Wired data transfer via integrated USB interface between photometer and PC/laptop
Pre-parameterised with the measurement curves of all parameters listed below
In addition to the parameters specified for the respective industry solution, the reagents listed below are available for photometric determination using the PPM 150. The corresponding data is available for a large number of other reagents from various manufacturers and can be compiled individually for the photometer on request.
Parameter
Measuring range
Order number
Ammonium
0,01-2,0
410681
Chlorine (free)
0-1,5
410521
Chlorine (total)
0-1,5
410521
Chlorine (bound)
0-1,5
410521
Chlorine dioxide
0-2,8
410525
Chloride
0-70
410527
Chromat
0-2,5
410533
Requirements Low
0-1,5
410548
Eisen High
0-10,0
410545
Hydrazin
0-1,0
410557
Copper
0-4,0
410563
Nitrite
0-1,0
410691
Phosphat
0-20,0
410593
Silicate
0-10,0
410623
Sulfit
0-20,0
410635
Hydrogen peroxide
0-20,0
410643
Language in the display:
German
|
Performance/execution:
230 V/50-60 HZ
The process photometer Testomat 2000® automatically determines water hardness, carbonate hardness, the p-value or the minus m-value via titration. It is ideal for monitoring the water quality of water treatment, water blending and drinking-water plants. Monitoring and quality control of softening plants with and without blending (Testomat 2000® reagent TH 2005–2250)Monitoring and quality control of decarbonisation plants (Testomat 2000® reagent TC 2050–2100) Measuring acidic values in decarbonisation and desalination plants (Testomat 2000® reagent TM 2005) Monitoring of steam boilers (Testomat 2000® reagent TP 2100).Performance profile:
Menu-driven operation and programming via plain text display
Determinal measuring ranges of residual hardness, total hardness, carbonate hardness, minus m value, p value by indicator selectionSelection of hardness units in ° dH, ° f, ppm CaCO3 or mmol / l
High-precision titration using a piston dosing pump
Analysis initiation:
- Automatic interval operation (Interval pause adjustable from 0–99 min)
- External control
- Dynamic (fatigue-dependent interval operation)
- Quantity dependent via contact water meter
Two independent limits with hysteresis (1, 2 oder 3 bad analyzes) and adjustable switching functionsMonitoring of two measuring points (Switching by external solenoid valves)Internal error documentation
Programmable service address
Indicator quantities: 100 and 500 ml bottles
Programmable maintenance interval for maintenance request
The Testomat® 808 is a compact analyzer for the online measurement of water hardness according to the principle of " limit value monitoring by color change ". The Testomat® style="letter-spacing: 0px;"> 808 is a combination of the latest technologies based upon decades of international Testomat® experience.Applications of continuous residual hardness monitoring are for example:
Reverse osmosis plants
Boiler feed water supply
Soft water for commercial puposes
Pure water systems
Performance profile:Limit value indication (not exceeded or exceeded: green / red LED)
Modern indicator pump system
Automatic measuring process with low water consumption
Direct error and indicator quantity indication
Internal and external flushing of the measuring chamber by manual control
Control of an external rinsing valve
Three potential-free relays for:
External rinsing valve control
Limit value evaluation
External control and / or alarm processing
Safety check for 72 hours operation without supervision
Indicator quantities: 100 and 500 ml bottles
4 - 20 mA interface for defined status and error messages
RS 232 interface for firmware updates
The Testomat® 808 SIO02 is a device that was developed for measuring and monitoring deionised water (fully demineralised water) in medical facilities.
The central importance of silicate monitoring
Silicate measurement using the Testomat® 808 SIO02 is an essential aspect of compliance with a defined limit value. Precise silicate monitoring is particularly important in process water treatment in hospitals in order to prevent deposits on devices and medical devices (MD) and to ensure the effectiveness of the water treatment systems. You can choose between 10 limit values in the range from 0.3 to 1.2 ppm. By regularly monitoring the silicate content and compliance with the limit values, potential problems can be identified at an early stage and suitable measures can be taken to optimise water treatment.
The Testomat® ECO / EVO automatically determines the water hardness by means of titration. The device is suitable for controlling the water quality of water treatment plants, drinking water systems, industrial boilers and for monitoring process water. Approved for boiler houses | component identification no.: TÜV. WÜH. 21-025 | VdTÜV bulletin water monitoring device 100 and UL-TÜV certified (only version with wide-range power supply unit).The Testomat® style="letter-spacing: 0px;"> EVO TH convinces with new functionalities:Optical water detection when filling the measuring chamber
BOB operation (operation without constant supervision)Import and export of settings (basic programming) with selectable file nameLogging of measurement data and messages / alarms using an integrated SD or optional SDHC card (2GByte)
Firmware update via SD card
LCD graphic display
Multilingual menu with easy switching (internal programming is retained)
Integrated self-test with continuous monitoring
External clear / acknowledge input
Free programmable password
Automatic bleeding of the indicator line
Doors can be changed individually
Range monitoring (fall below limit value1 / exceed limit value 2)
Permitted number of lack of water, freely programmable (for systems with temporarily low water pressure)[#mspacer#]Performance profile:High-precision titration using a piston dosing pump
Analogue output 0/4 - 20 mA
Serial RS232 interface for transfer of measurement data and messages/alarmsProgrammable hardness unit in ° dH, ° f, ppm CaCO3, mmol / l
2 independent limits with adjustable switching functions as well as switching option in accordance with an adjustable number of negativeanalyzes
Analysis initiation:
automatic interval operation (0-99 minutes)
depending on quantity via contact water meter
Indicator quantities: 100 und 500 ml bottles
The Testomat® EVO TH is supplied without a power switch. This is done to comply with the DIN EN 61010-1 safety standard for measuring, control and laboratory equipment. Of course, an external mains switch will be made available to you as a customer for purchase. You can order this from us as a disconnector under article no. 850925, "external cam switch with protection class IP65".
The Testomat® EVO TH automatically determines the water hardness by means of titration. The device is suitable for controlling the water quality of water treatment plants, drinking water systems, industrial boilers and for monitoring process water. On top of that our Testomat® EVO TH is approved for boiler houses | component identification no.: TÜV. WÜH. 21-025 | VdTÜV bulletin water monitoring device 100 and UL-TÜV certified.
It is supplemented by the Testomat® LAB CL, a robust wet chemical online measuring converter to measure the concentration of total chlorine or free chlorine in the measuring range 0 - 5 mg/l. The instrument is suitable for controlling the water quality of water treatment plants, drinking water plants, process water monitoring and for monitoring the chlorine concentration in the cooling tower process. Instrument operation is based on the DPD method according to EN ISO 7393-2. The analysis is carried out through the addition of two reagents and the measurement result is obtained after a reaction time of approx. 60 seconds (pure measurement time without flush time).
In view of the fact that the Testomat® LAB CL was developed for use in multi-parameter systems or for connection to a higher-level control system, we hereby offer you the Testomat® EVO TH and the Testomat® LAB CL in combination with the NeoTecMaster®, which was specially developed by our company, as a package solution at a preferential price.
The 4-channel NeoTecMaster® multi-parameter controller included in this package enables the processing of up to four measurement signals in this version. A signal input on the NeoTecMaster® , in this case the RS232 interface and one additional RS232 interface on the included NeoTec Slave module , are used by Testomat® EVO TH and Testomat® LAB CL to display the measured value, the trend and the status messages on the 5 inch screen. In addition to the on board RS232 interface, the NeoTecMaster® also has a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments).
The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required, thus enabling the future realisation of further control concepts in a flexible manner. A module that fundamentally expands the range of functions and is already included in the scope of delivery is our NeoTec slave relay module with which you can add potential-free relay contacts to the overall system. You can freely assign these to the incoming measurement signals and thus, for example, implement limit value-related control concepts, as well as output measurement-related messages.
Further advantages of the NeoTecMaster:
Simple operation
Integration of the Testomat® world of instruments, here in conjunction with the Testomat® EVO TH and Testomat® LAB CL
Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® housing
Modular range of functions can be extended by NeoTec slave and signal converter modules (measurement, control, regulation)
Available as built-in or surface-mounted variant Structured continuous data recording on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format
In addition, there are proven Testomat® functionalities of both devices:
Optimised water detection based on an optical measuring method
RS232 interface for transmission of measured values and error messages
Import and export of settings (basic programming)
Logging of measurement data and messages/alarms via integrated SD card or optionally usable SDHC card (2GByte)
Firmware update via SD card
Integrated self-test with continuous monitoring
Automatic venting of the indicator line
Performance profil Testomat® EVO TH:
High-precision titration by means of piston metering pump
LCD graphic display
Multilingual menu with easy switching (internal programming is retained)
External clear / acknowledge input
Free programmable password
Range monitoring (fall below limit value1 / exceed limit value 2)
Permitted number of lack of water, freely programmable (for systems with temporarily low water pressure)
Reliable and low-maintenance operation
Minimal indicator and water consumption
Analogue output 4 - 20 mA for transmission of measured values
Programmable hardness unit in °dH, °f, ppm CaCO3, mmol/l
Collective alarm output
Indicator quantities: 100 and 500 ml bottles
Analysis trigger:
automatic interval operation (0-99 minutes)
depending on quantity via contact water meter
Performance profil Testomat® LAB CL:
High-precision peristaltic pumps
Reliable and low-maintenance operation
Minimal reagent and water consumption
Analog output 4 - 20 mA for transmission of measured values
RS232 interface for transmission of measured values & fault messages
Execution of parameterisation by means of SD card or "Service Monitor" software via mini-USB (on the unit side) to USB 2.0 (e.g. PC/notebook)
Multilingual software menu in German, English, French, Dutch, Portoguese
Compact design
Common alarm output
Optimised reagents: Only 2 reagents for the determination of total chlorine
Optimised reagent set: filling quantities are coordinated so that the reagent set is used up almost evenly
Analysis triggering:
Automatic interval operation (interval pause adjustable from 10-60 minutes)
Measuring phase mode (start impulse triggers a sequence of analyses for a period of 10 minutes to 12 hours)
External analysis input (start/stop)
Hand start
Optional accessories available:
OLED display for Testomat® LAB
Protective cover to increase the IP protection class of the Testomat® LAB
NeoTecMaster instrument cover
The Testomat® LAB CL and the Testomat® LAB CL-R are robust, wet chemical online measuring converter to measure the concentration of total chlorine or free chlorine in the measuring range 0 - 5 mg/l. The instrument is suitable for controlling the water quality of water treatment plants, drinking water plants, process water monitoring and for monitoring the chlorine concentration in the cooling tower process.Instrument operation is based on the DPD method according to EN ISO 7393-2. The analysis is carried out through the addition of two reagents and the measurement result is obtained after a reaction time of approx. 60 seconds (pure measurement time without flush time).Please note that Testomat® LAB CL and Testomat® LAB CL-R are developed for use in multi-parameter concepts or for integration into an existing higher-level controlconcept.In addition to the 4-20 mA output for the transmission of the measured values, this series has an RS232 interface for the transmission of the measured values and error & status messages. Furthermore, all data are continuously recorded on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format in a structured way and can be used for detailed observations at any time.The Testomat® LAB CL and CL-R convinces with new functionalities:Execution of parameterization by SD card or the "Service Monitor" software via mini-USB (on the device side) to USB 2.0 (for example PC/notebook)Multilingual menu navigation software in German, English, French, Dutch, PortugueseFirmware update via SD card
compact design
optimized water detection based on an optical measuring method [#dspacer#][#dspacer#]optimized reagent set for total chlorine measurement (reduction from three to tow reagents for total chlorine)Integrated self-test with continuous monitoring
Automatic venting of the indicator line Tried and tested performance profile: High-precision peristaltic pumpsReliable and low-maintenance operation
Minimal reagent and water consumption
Analog output 4 - 20 mA for transmission of measured values
RS232 interface for transmission of measured values & fault messages
Common alarm output
Optimised reagents: Only 2 reagents for the determination of total chlorineOptimised reagent bottles: Filling quantities adjusted so that both bottles are used up at the same timeAdditional functions of the CL-R version: Parameterisation and readout of the unit parameters via the RS232 interfaceAnalysis triggering:Automatic interval operation (interval pause adjustable from 10-60 minutes)
Measuring phase mode (start impulse triggers a sequence of analyses for a period of 10 minutes to 12 hours)
External analysis input (start/stop)
Hand start
The Testomat® LAB CL is a robust wet chemical online measuring converter to measure the concentration of total chlorine or free chlorine in the measuring range 0 - 5 mg/l. The instrument is suitable for controlling the water quality of water treatment plants, drinking water plants, process water monitoring and for monitoring the chlorine concentration in the cooling tower process. Instrument operation is based on the DPD method according to EN ISO 7393-2. The analysis is carried out through the addition of two reagents and the measurement result is obtained after a reaction time of approx. 60 seconds (pure measurement time without flush time).
In view of the fact that the Testomat® LAB CL was developed for use in multi-parameter systems or for connection to a higher-level control system, we hereby offer you the Testomat® LAB CL in combination with the NeoTecMaster® Multi Channel Controller, which was specially developed by our company, as a package solution at a preferential price.
The 4-channel NeoTecMaster® multi-parameter controller included in this package enables the processing of up to four measurement signals in this version. A signal input, in this case the RS232 interface, is used by the Testomat® LAB CL to display the measured value, the trend and the status messages on the 5 inch screen.
In addition to the on board RS232 interface, the NeoTecMaster® also has a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments).
The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required, thus enabling the future realisation of further control concepts in a flexible manner.
Two modules that fundamentally expand the range of functions and are already included in the scope of delivery are our NeoTec slave relay module and the 4x 4-20mA output module. This allows you to add potential-free relay contacts to the overall system and to realise linear or inverted dosing processes via the 4x 4-20mA output module. You can freely assign the relay contacts to the incoming measurement signals and thus, for example, also implement simple limit value-related control concepts, as well as output measurement value-related messages. Via the 4-20mA output module, you can also forward the measured values to a higher-level controller as desired.
Further advantages of the NeoTecMaster:
Simple operation
Integration of the Testomat® world of instruments, here in conjunction with the Testomat® LAB CL
Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® housing
Modular range of functions can be extended by NeoTec slave and signal converter modules (measurement, control, regulation)
Available as built-in or surface-mounted variant Structured continuous data recording on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format
In addition, there are proven Testomat® LAB functionalities:
Optimised water detection based on an optical measuring method
RS232 interface for transmission of measured values and error messages
Import and export of settings (basic programming)
Logging of measurement data and messages/alarms via integrated SD card or optionally usable SDHC card (2GByte)
Firmware update via SD card
Integrated self-test with continuous monitoring
Automatic venting of the indicator line
Performance profil Testomat® LAB CL:
High-precision peristaltic pumps
Reliable and low-maintenance operation
Minimal reagent and water consumption
Analog output 4 - 20 mA for transmission of measured values
RS232 interface for transmission of measured values & fault messages
Execution of parameterisation by means of SD card or "Service Monitor" software via mini-USB (on the unit side) to USB 2.0 (e.g. PC/notebook)
Multilingual software menu in German, English, French, Dutch, Portuguese
Compact design
Common alarm output
Optimised reagents: Only 2 reagents for the determination of total chlorine
Optimised reagent set: filling quantities are coordinated so that the reagent set is used up almost evenly
Analysis triggering:
Automatic interval operation (interval pause adjustable from 10-60 minutes)
Measuring phase mode (start impulse triggers a sequence of analyses for a period of 10 minutes to 12 hours)
External analysis input (start/stop)
Hand start
Optional accessories available:
OLED display for Testomat® LAB
Protective cover to increase the IP protection class of the Testomat® LAB
NeoTecMaster instrument cover
The Testomat® LAB CL and the Testomat® LAB CL-R are robust, wet chemical online measuring converter to measure the concentration of total chlorine or free chlorine in the measuring range 0 - 5 mg/l. The instrument is suitable for controlling the water quality of water treatment plants, drinking water plants, process water monitoring and for monitoring the chlorine concentration in the cooling tower process.Instrument operation is based on the DPD method according to EN ISO 7393-2. The analysis is carried out through the addition of two reagents and the measurement result is obtained after a reaction time of approx. 60 seconds (pure measurement time without flush time).Please note that Testomat® LAB CL and Testomat® LAB CL-R are developed for use in multi-parameter concepts or for integration into an existing higher-level controlconcept.In addition to the 4-20 mA output for the transmission of the measured values, this series has an RS232 interface for the transmission of the measured values and error & status messages. Furthermore, all data are continuously recorded on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format in a structured way and can be used for detailed observations at any time.The Testomat® LAB CL and CL-R convinces with new functionalities:Execution of parameterization by SD card or the "Service Monitor" software via mini-USB (on the device side) to USB 2.0 (for example PC/notebook)Multilingual menu navigation software in German, English, French, Dutch, PortugueseFirmware update via SD card
compact design
optimized water detection based on an optical measuring method [#dspacer#][#dspacer#]optimized reagent set for total chlorine measurement (reduction from three to tow reagents for total chlorine)Integrated self-test with continuous monitoring
Automatic venting of the indicator line Tried and tested performance profile: High-precision peristaltic pumpsReliable and low-maintenance operation
Minimal reagent and water consumption
Analog output 4 - 20 mA for transmission of measured values
RS232 interface for transmission of measured values & fault messages
Common alarm output
Optimised reagents: Only 2 reagents for the determination of total chlorineOptimised reagent bottles: Filling quantities adjusted so that both bottles are used up at the same timeAdditional functions of the CL-R version: Parameterisation and readout of the unit parameters via the RS232 interfaceAnalysis triggering:Automatic interval operation (interval pause adjustable from 10-60 minutes)
Measuring phase mode (start impulse triggers a sequence of analyses for a period of 10 minutes to 12 hours)
External analysis input (start/stop)
Hand start
The Testomat® LAB Monochloramine NH2CL and the
Testomat® LAB Monochloramine NH2CL-R
are online analyzer that photometrically measures the content of monochloramine in process water. The instruments are used for continuous monitoring of process quality, for example in cooling circuits. Another application is the use in the environment of water treatment and drinking water plants, for process monitoring, as well as the monitoring of ther decay behavior in cooling towers after shock chlorination. The measuring range
for Monochloramine (NH2CL, calculated as Cl2)
is 0 to 5 ppm (resolution 0.1). The instruments operates according to the DPD method based on EN ISO 7393-2. The analysis is performed by adding two reagents. After a reaction time of approx. 60 seconds (dosing and measuring time without rinsing time) the measuring result is available. Please note that the Testomat® Monochloramine NH2CL and NH2CL-R are developed for use in multiparameter systems or for connection to a higher-level control system. In addition to the 4-20 mA output for transmitting the measured values, this series has an RS232 interface for transmitting the measured values and error & status messages. Furthermore, all data are continuously recorded on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format structured and can be used at any time for detailed observations.The Testomat® LAB Monochloramine NH2CL and NH2CL-R convinces with new functionalities:Execution of parameterization by SD card or the "Service Monitor" software via mini-USB (on the device side) to USB 2.0 (for example PC/notebook)Multilingual menu navigation software in German, English, French, DutchFirmware update via SD card
compact design
optimized water detection based on an optical measuring methodoptimized reagent set for total chlorine measurement (reduction from three to tow reagents for total chlorine)Integrated self-test with continuous monitoring
Automatic venting of the indicator line
Additional functions of the NH2CL-R version: Parameterisation and readout of the unit parameters via the RS232 interface
Tried and tested performance profile: High-precision peristaltic pumpsReliable and low-maintenance operation
Minimal reagent and water consumption
Analog output 4 - 20 mA for transmission of measured values
RS232 interface for transmission of measured values & fault messages
Common alarm outputAnalysis triggering:
Automatic interval operation (interval pause adjustable from 10-60 minutes)
Measuring phase mode (start impulse triggers a sequence of analyses for a period of 10 minutes to 12 hours)
External analysis input (start/stop)
Hand start
The Testomat® LAB Monochloramine (NH2CL) is an online analyser that photometrically measures the content of monochloramine in process water and is used for continuous monitoring of process quality, for example in cooling circuits. Another area of application is the use in the environment of water treatment and drinking water plants, for process monitoring, as well as monitoring the decay behaviour in cooling towers after shock chlorination.
The measuring range for monochloramine (NH2CL, calculated as Cl2) is 0 to 5 ppm (resolution 0.1). The instrument works according to the DPD method based on EN ISO 7393-2 and the analysis is carried out by adding two reagents. After a reaction time of approx. 60 seconds (dosing and measuring time without rinsing time) the measuring result is available.
For the transmission of the measured values, in addition to the 4-20mA signal output, an RS232 interface is available for the transmission of the measured values as well as error & status messages. Furthermore, all data are continuously recorded on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format and can be used for detailed observations at any time.
In view of the fact that the Testomat® LAB Monochloramine was developed for use in multi-parameter systems or for connection to a higher-level control system, we hereby offer you the Testomat® LAB Monochloramine in conjunction with the NeoTecMaster® Multicontroller, which was specially developed by our company, as a package solution at a preferential price.
The 4-channel NeoTecMaster® Multicontroller included in this package enables the processing of up to four measurement signals in this version. One signal input on the NeoTecMaster®, in this case the RS232 interface, is used by Testomat® LAB Monochloramine to display the measured value, the trend and the status messages on the 5 inch screen.
In addition to the RS232 interface, the NeoTecMaster® also has a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments).
The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required. This allows the future realisation of further control concepts in a flexible way. Two modules which fundamentally extend the range of functions and are already included in the scope of delivery are our NeoTec slave relay module and the 4x 4-20mA output module. This allows you to add potential-free relay contacts to the overall system and to realise linear or inverted dosing processes via the 4x 4-20mA output module. You can freely assign the relay contacts to the incoming measurement signals and thus, for example, also implement simple limit value-related control concepts, as well as output measurement value-related messages. Via the 4-20mA output module, you can also forward the measured values to a higher-level controller as desired.
Further advantages of the NeoTecMaster:
Simple operation Integration of the Testomat® world of instruments, here in connection with the Testomat® LAB Monochloramine
Integration into the existing control cabinet, alternatively we offer you our NeoTecMaster® housing
Modular range of functions can be extended by NeoTec slave and signal converter modules (measurement, control, regulation)
Available as built-in or surface-mounted variant
Structured continuous data recording on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format
In addition, there are proven Testomat® LAB functionalities:
Optimised water detection based on an optical measuring method
RS232 interface for transmission of measured values and error messages
Import and export of settings (basic programming)
Logging of measurement data and messages/alarms via integrated SD card or optionally usable SDHC card (2GByte)
Firmware update via SD card
Integrated self-test with continuous monitoring
Automatic venting of the indicator line
Performance profil Testomat® LAB Monochloramine:
High-precision peristaltic pumps
Reliable and low-maintenance operation
Minimal reagent and water consumption
Analog output 4 - 20 mA for transmission of measured values
RS232 interface for transmission of measured values & fault messages
Execution of parameterisation by means of SD card or "Service Monitor" software via mini-USB (on the unit side) to USB 2.0 (e.g. PC/notebook)
Multilingual software menu in German, English, French, Dutch
Compact design
Common alarm output
Optimised reagents: Only 2 reagents for the determination of monochloramine (NH2CL)
Optimised reagent set: filling quantities are coordinated so that the reagent set is used up almost evenly
Analysis triggering:
Automatic interval operation (interval pause adjustable from 10-60 minutes)
Measuring phase mode (start impulse triggers a sequence of analyses for a period of 10 minutes to 12 hours)
External analysis input (start/stop)
Hand start
Optional accessories available:
OLED display for Testomat® LAB
Protective cover to increase the IP protection class of the Testomat® LAB
NeoTecMaster instrument cover
The Testomat® LAB Monochloramine NH2CL and the
Testomat® LAB Monochloramine NH2CL-R
are online analyzer that photometrically measures the content of monochloramine in process water. The instruments are used for continuous monitoring of process quality, for example in cooling circuits. Another application is the use in the environment of water treatment and drinking water plants, for process monitoring, as well as the monitoring of ther decay behavior in cooling towers after shock chlorination. The measuring range
for Monochloramine (NH2CL, calculated as Cl2)
is 0 to 5 ppm (resolution 0.1). The instruments operates according to the DPD method based on EN ISO 7393-2. The analysis is performed by adding two reagents. After a reaction time of approx. 60 seconds (dosing and measuring time without rinsing time) the measuring result is available. Please note that the Testomat® Monochloramine NH2CL and NH2CL-R are developed for use in multiparameter systems or for connection to a higher-level control system. In addition to the 4-20 mA output for transmitting the measured values, this series has an RS232 interface for transmitting the measured values and error & status messages. Furthermore, all data are continuously recorded on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format structured and can be used at any time for detailed observations.The Testomat® LAB Monochloramine NH2CL and NH2CL-R convinces with new functionalities:Execution of parameterization by SD card or the "Service Monitor" software via mini-USB (on the device side) to USB 2.0 (for example PC/notebook)Multilingual menu navigation software in German, English, French, DutchFirmware update via SD card
compact design
optimized water detection based on an optical measuring methodoptimized reagent set for total chlorine measurement (reduction from three to tow reagents for total chlorine)Integrated self-test with continuous monitoring
Automatic venting of the indicator line
Additional functions of the NH2CL-R version: Parameterisation and readout of the unit parameters via the RS232 interface
Tried and tested performance profile: High-precision peristaltic pumpsReliable and low-maintenance operation
Minimal reagent and water consumption
Analog output 4 - 20 mA for transmission of measured values
RS232 interface for transmission of measured values & fault messages
Common alarm outputAnalysis triggering:
Automatic interval operation (interval pause adjustable from 10-60 minutes)
Measuring phase mode (start impulse triggers a sequence of analyses for a period of 10 minutes to 12 hours)
External analysis input (start/stop)
Hand start
The Testomat® LAB TH and Testomat® LAB TH-R (Remote)determine the water hardness (residual total hardness) fully automatically by titration. The instrument is suitable for controlling the water quality of water treatment plants, drinking water plants, industrial boilers and for monitoring process water.Please note that Testomat® LAB - TH
and Testomat® LAB TH-R was developed for use in multi-parameter systems or for connection to a higher-level control system.
In addition to the 4-20 mA output for transmitting the measured values, this series has an RS232 interface for transmitting the measured values and error & status messages. Furthermore, all data are continuously recorded on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format structured and can be used at any time for detailed observations.The Testomat® LAB TH and TH-R convinces with new functionalities:
Execution of parameterization by SD card or the "Service Monitor" software via mini-USB (on the device side) to USB 2.0 (for example PC/notebook)Multilingual menu navigation software in German, English, French, Dutch, PortugueseFirmware update via SD card
compact design
optimized water detection based on an optical measuring method
Integrated self-test with continuous monitoring
Automatic venting of the indicator line [#mspacer#]Additional functions of the TH-R version:Parameterisation and readout of the unit parameters
via the RS232 interfaceTried and tested performance profile:
High-precision titration using a piston dosing pump
Reliable and low-maintenance operation
Minimal indicator and water consumption
Analog output 4 - 20 mA for transmission of measured values
Programmable hardness unit in °dH, °f, ppm CaCO3, mmol/l
Common alarm output
Indicator quantities: 500 ml bottles
Analysis triggering:
Automatic interval operation (interval pause adjustable from 0-255 minutes)
External analysis input (start/stop)
Hand launchOptional accessories:
OLED display
Protecting cover to increase the IP protection class
The Testomat® LAB TH determines the water hardness (residual total hardness) fully automatically by use of titration and has been developed for monitoring the water quality of water treatment plants, drinking water plants, industrial boilers and for monitoring process water and the Testomat® LAB CL is a robust, wet chemical online measuring converter to measure the concentration of total chlorine or free chlorine in the measuring range 0 - 5 mg/l. The instrument is suitable for controlling the water quality of water treatment plants, drinking water plants, process water monitoring and for monitoring the chlorine concentration in the cooling tower process. Instrument operation is based on the DPD method according to EN ISO 7393-2. The analysis is carried out through the addition of two reagents and the measurement result is obtained after a reaction time of approx. 60 seconds (pure measurement time without flush time).
In view of the fact that the Testomat® LAB TH and Testomat® LAB CL was developed for use in multi-parameter systems or for connection to a higher-level control system, we hereby offer you both Testomat® LAB analysis devices in combination with the NeoTecMaster®, which was specially developed by our company, as a package solution at a preferential price.
The 4-channel NeoTecMaster® multi-parameter controller included in this package enables the processing of up to four measurement signals in this version. A signal input on the NeoTecMaster® , in this case the RS232 interface and one additional RS232 interface on the included NeoTec Slave module , are used by Testomat® LAB TH and Testomat® LAB CL to display the measured value, the trend and the status messages on the 5 inch screen. In addition to the on board RS232 interface, the NeoTecMaster® also has a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments).
The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required, thus enabling the future realisation of further control concepts in a flexible manner. A module that fundamentally expands the range of functions and is already included in the scope of delivery is our NeoTec slave relay module with which you can add potential-free relay contacts to the overall system. You can freely assign these to the incoming measurement signals and thus, for example, implement limit value-related control concepts, as well as output measurement-related messages.
Further advantages of the NeoTecMaster:
Simple operation Integration of the Testomat® world of instruments, here in conjunction with the Testomat® LAB TH and Testomat® LAB CL
Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® housing
Modular range of functions can be extended by NeoTec slave and signal converter modules (measurement, control, regulation)
Available as built-in or surface-mounted variant Structured continuous data recording on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format
In addition, there are proven Testomat® LAB functionalities:
Optimised water detection based on an optical measuring method
RS232 interface for transmission of measured values and error messages
Import and export of settings (basic programming)
Logging of measurement data and messages/alarms via integrated SD card or optionally usable SDHC card (2GByte)
Firmware update via SD card
Execution of parameterisation by means of SD card or "Service Monitor" software via mini-USB (on the unit side) to USB 2.0 (e.g. PC/notebook)
Multilingual software menu in German, English, French, Dutch; Portuguese
Integrated self-test with continuous monitoring
Automatic venting of the indicator line
Compact design
Performance profil Testomat® LAB TH:
High-precision titration by means of piston metering pump
Reliable and low-maintenance operation
Minimal indicator and water consumption
Analogue output 4 - 20 mA for transmission of measured values
Programmable hardness unit in °dH, °f, ppm CaCO3, mmol/l
Collective alarm output
Indicator quantities: 500 ml bottles
Analysis trigger:
- Automatic interval operation (interval pause adjustable from 0-255 minutes) - External analysis input (start/stop) - Manual start
Performance profil Testomat® LAB CL:
High-precision peristaltic pumps
Reliable and low-maintenance operation
Minimal reagent and water consumption
Analog output 4 - 20 mA for transmission of measured values
RS232 interface for transmission of measured values & fault messages
Common alarm output
Optimised reagents: Only 2 reagents for the determination of total chlorine
Optimised reagent set: filling quantities are coordinated so that the reagent set is used up almost evenly.
Analysis trigger:
Automatic interval operation (interval pause adjustable from 0-255 minutes)
External analysis input (start/stop)
Manual start
Optional accessories available:
OLED display
Protective cover to increase the IP protection class of the Testomat® LAB devices
NeoTecMaster instrument cover
The Testomat® LAB TH and Testomat® LAB TH-R (Remote)determine the water hardness (residual total hardness) fully automatically by titration. The instrument is suitable for controlling the water quality of water treatment plants, drinking water plants, industrial boilers and for monitoring process water.Please note that Testomat® LAB - TH
and Testomat® LAB TH-R was developed for use in multi-parameter systems or for connection to a higher-level control system.
In addition to the 4-20 mA output for transmitting the measured values, this series has an RS232 interface for transmitting the measured values and error & status messages. Furthermore, all data are continuously recorded on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format structured and can be used at any time for detailed observations.The Testomat® LAB TH and TH-R convinces with new functionalities:
Execution of parameterization by SD card or the "Service Monitor" software via mini-USB (on the device side) to USB 2.0 (for example PC/notebook)Multilingual menu navigation software in German, English, French, Dutch, PortugueseFirmware update via SD card
compact design
optimized water detection based on an optical measuring method
Integrated self-test with continuous monitoring
Automatic venting of the indicator line [#mspacer#]Additional functions of the TH-R version:Parameterisation and readout of the unit parameters
via the RS232 interfaceTried and tested performance profile:
High-precision titration using a piston dosing pump
Reliable and low-maintenance operation
Minimal indicator and water consumption
Analog output 4 - 20 mA for transmission of measured values
Programmable hardness unit in °dH, °f, ppm CaCO3, mmol/l
Common alarm output
Indicator quantities: 500 ml bottles
Analysis triggering:
Automatic interval operation (interval pause adjustable from 0-255 minutes)
External analysis input (start/stop)
Hand launchOptional accessories:
OLED display